Tools needed: LN-26 Hex Screw Driver

Unplug machine from the power source.  Remove Access Hole Cover E575 and Button Hole Plug E695. With the LN-26 Hex Screw Driver, go through the hole left by the removal of the hole plug, and loosen the EA5 Cap Screw.  Move the Radius Plate in a counter clockwise direction to shorten lengths, and in a clockwise direction to lengthen.  Retighten Cap Screw to secure.